title: ВСлСмСтрия & Π‘Π΅Π½Π·ΠΎΡ€ΠΈ
parent: Π ΡŠΠΊΠΎΠ²ΠΎΠ΄ΡΡ‚Π²ΠΎ Π·Π° ΠΏΠΎΡ‚Ρ€Π΅Π±ΠΈΡ‚Π΅Π»ΠΈ
nav_order: 9
last_updated: 2026-05-13
description: Sensor data on the mesh β€” supported environment, air quality, and power sensors, plus configuration and viewing guides.
aliases:
β€’ сСнзори
β€’ ΠΎΠΊΠΎΠ»Π½Π° срСда
β€’ Π²Ρ€Π΅ΠΌΠ΅Ρ‚ΠΎ
β€’ power-metrics

ВСлСмСтрия & Π‘Π΅Π½Π·ΠΎΡ€ΠΈ

Meshtastic nodes can collect and share sensor data across the mesh network.

ΠŸΡ€Π΅Π³Π»Π΅Π΄

Telemetry allows nodes equipped with sensors to broadcast environmental, power, and device health information. This data is visible on the node detail screen and can be logged over time.

Device Telemetry

All Meshtastic nodes report basic device telemetry:

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ ΠœΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈ β”‚ ОписаниС β”‚ Π’ΠΈΠΏΠΈΡ‡Π΅Π½ Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½ β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Ниво Π½Π° батСрията β”‚ Charge percentage β”‚ 0–100% β”‚
β”‚ НапрСТСниС β”‚ НапрСТСниС Π½Π° батСрията β”‚ 3.0–4.2V (LiPo) β”‚
β”‚ ИзползванС Π½Π° ΠΊΠ°Π½Π°Π»Π° β”‚ % of airtime used locally β”‚ 0–100% β”‚
β”‚ Air Utilization TX β”‚ % of airtime used by this node β”‚ 0–100% β”‚
β”‚ Π’Ρ€Π΅ΠΌΠ΅ Π½Π° Ρ€Π°Π±ΠΎΡ‚Π° β”‚ Seconds since last boot β”‚ Varies β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

Π‘Π΅Π½Π·ΠΎΡ€ΠΈ Π·Π° ΠΎΠΊΠΎΠ»Π½Π° срСда

ΠŸΠΎΠ΄Π΄ΡŠΡ€ΠΆΠ°Π½ΠΈ сСнзори Π·Π° ΠΎΠΊΠΎΠ»Π½Π° срСда:

Π’Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π° & ВлаТност

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ Π‘Π΅Π½Π·ΠΎΡ€ β”‚ Π’Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π° β”‚ ВлаТност β”‚ НаляганС β”‚ Π‘Π΅Π»Π΅ΠΆΠΊΠΈ β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ BME280 β”‚ βœ“ β”‚ βœ“ β”‚ βœ“ β”‚ ΠŸΡ€Π΅ΠΏΠΎΡ€ΡŠΡ‡ΠΈΡ‚Π΅Π»Π½ΠΎ ΠΌΠ½ΠΎΠ³ΠΎΡ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»Π½ΠΎ устройство β”‚
β”‚ BME680 β”‚ βœ“ β”‚ βœ“ β”‚ βœ“ β”‚ Adds gas resistance/IAQ β”‚
β”‚ SHT31 β”‚ βœ“ β”‚ βœ“ β”‚ β€” β”‚ Висока точност β”‚
β”‚ MCP9808 β”‚ βœ“ β”‚ β€” β”‚ β€” β”‚ ΠŸΡ€Π΅Ρ†ΠΈΠ·Π½Π° Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π° β”‚
β”‚ LPS22 β”‚ β€” β”‚ β€” β”‚ βœ“ β”‚ Π‘Π°ΠΌΠΎ наляганС β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

ΠšΠ°Ρ‡Π΅ΡΡ‚Π²ΠΎ Π½Π° Π²ΡŠΠ·Π΄ΡƒΡ…Π°

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ Π‘Π΅Π½Π·ΠΎΡ€ β”‚ ΠœΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈ β”‚ Π‘Π΅Π»Π΅ΠΆΠΊΠΈ β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ BME680 β”‚ Gas Resistance / IAQ β”‚ Volatile organic compounds β”‚
β”‚ PMSA003I β”‚ PM1.0, PM2.5, PM10 β”‚ Particulate matter β”‚
β”‚ SEN55 β”‚ PM, NOx, VOC, Temp, Humidity β”‚ Multi-sensor β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

Π‘Π²Π΅Ρ‚Π»ΠΈΠ½Π° & UV

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ Π‘Π΅Π½Π·ΠΎΡ€ β”‚ ΠœΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈ β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ OPT3001 β”‚ Околна свСтлина (lux) β”‚
β”‚ VEML7700 β”‚ Околна свСтлина (lux) β”‚
β”‚ LTR390 β”‚ UV индСкс β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

ΠŸΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΠΈ Π½Π° мощност

Nodes with INA-series power sensors can report:

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ ΠœΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈ β”‚ ОписаниС β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Bus Voltage β”‚ Supply rail voltage β”‚
β”‚ Π’Π΅ΠΊΡƒΡ‰ β”‚ Power consumption (mA) β”‚
β”‚ Π—Π°Ρ…Ρ€Π°Π½Π²Π°Π½Π΅ β”‚ Calculated power (mW) β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

Useful for monitoring solar charging or battery health on remote nodes.

Configuring Telemetry

1. Navigate to Settings β†’ Module Config β†’ Telemetry.
2. Set reporting intervals:
β€’ Device Metrics Interval β€” how often to broadcast device metrics
β€’ Environment Metrics Interval β€” how often to broadcast sensor data
3. Enable specific sensor types as needed.

Recommended Intervals

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ Use Case β”‚ Device (s) β”‚ Environment (s) β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ Urban mesh (many nodes) β”‚ 3600 β”‚ 3600 β”‚
β”‚ Rural mesh (few nodes) β”‚ 900 β”‚ 900 β”‚
β”‚ ΠœΠ΅Ρ‚Π΅ΠΎΡ€ΠΎΠ»ΠΎΠ³ΠΈΡ‡Π½Π° станция β”‚ 900 β”‚ 300 β”‚
β”‚ Battery conservation β”‚ 7200 β”‚ 7200 β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

β”‚ ⚠️ Note: Shorter intervals increase airtime usage and battery drain across the mesh.

Air Quality Metrics

Nodes with particulate matter or COβ‚‚ sensors report air quality data:

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ ΠœΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈ β”‚ Unit β”‚ ОписаниС β”‚
β”œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”Όβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€
β”‚ PM1.0 β”‚ Β΅g/mΒ³ β”‚ Ultrafine particulate matter β”‚
β”‚ PM2.5 β”‚ Β΅g/mΒ³ β”‚ Fine particulate matter β”‚
β”‚ PM10 β”‚ Β΅g/mΒ³ β”‚ Coarse particulate matter β”‚
β”‚ COβ‚‚ β”‚ ppm β”‚ Carbon dioxide concentration β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜

The COβ‚‚ reading is color-coded by severity:

β€’ 🟒 Good (< 1000 ppm) β€” normal indoor levels
β€’ 🟑 Moderate (1000–2000 ppm) β€” elevated, consider ventilation
β€’ 🟠 Poor (2000–5000 ppm) β€” drowsiness, poor concentration
β€’ πŸ”΄ Hazardous (β‰₯ 5000 ppm) β€” immediate health concern

Air quality data can be viewed as info cards on the node detail screen, charted over time, and exported to CSV.

Viewing Telemetry

1. Navigate to Nodes and select a node.
2. Telemetry sections show on the detail screen:
β€’ Device Metrics (always available)
β€’ Environment Metrics (if sensors present)
β€’ Power Metrics (if INA sensor present)
β€’ Air Quality Metrics (if PM/COβ‚‚ sensor present)
3. Historical graphs show trends over time.


ΠžΡ‚ΡΡ‚Ρ€Π°Π½ΡΠ²Π°Π½Π΅ Π½Π° нСизправности

β€’ No environment data showing? The remote node needs a physical sensor connected (e.g., BME280 on I2C). Device telemetry (battery, uptime) is always available, but environment metrics require hardware.
β€’ Stale readings? Check the reporting interval β€” very long intervals (7200s+) mean data updates infrequently. Also verify the remote node is still online.
β€’ Sensor conflict on I2C bus? Some sensors share I2C addresses. If you have multiple sensors on the same bus, check for address collisions in the radio's serial debug output.